HTB series small and medium-sized dual section fire gas burner
keyword:
Category:
HT series all-in-one gas burner adopts natural gas and LPG as fuel, and is divided into single-stage fire, double-stage fire and proportional adjustment type according to the operation control mode.
1、Single-stage fire: only one section of fire output, the operation mode is on/off type. The use of single-stage fire is generally a low-power burner.
2、Double-stage fire: there are two stages of fire power, large and small fire, according to the control of the boiler thermostat (or pressure controller) to achieve a small fire (a fire) / large fire (= fire) 1 off conversion between the operation.
3, proportional adjustment type: can achieve smooth, proportional adjustment of the combustion volume in the output range. According to the signal from the equipment temperature or pressure controller, the burner can operate at any working point in the output range to keep the balance of the system input and output load and meet the system requirements for high-precision load control.
Natural gas (NG, LNG), liquefied petroleum gas (LPG) as the fuel, fully automatic dual-stage fire (large / small fire) mode control, according to the equipment load control can be automatically switched between large / small fire, to meet the needs of higher precision load control.
Widely used in small and medium-sized boilers, heating furnaces, spraying equipment, drying equipment, heat treatment equipment and other thermal equipment, to achieve certain load control accuracy requirements of the application.
▪ Safe and reliable fully automatic program control
◎ Fully automatic program control operation, which can control high / low fire switching according to the load parameter setting and realize automatic control of output size;
◎ The use of ion induction or UV type flame detection device to achieve accidental flame out protection function, to ensure the flame burning safety and stability;
◎ Equipped with gas, pressure and air pressure safety protection switch, while the external chain control can be easily realized to ensure safe operation.
Good combustion performance
◎ The combustion volume of large and small fire state can be set freely in the output range, and the load output control is more flexible and convenient;
The air volume can be adjusted automatically and synchronously according to the setting when switching between large and small fires to ensure the best combustion status in both large and small fires.
The configuration can be increased flexibly
◎ Proportional control of small and medium-sized burners can be achieved by adding a proportional regulator to meet the demand for more accurate load control;
◎ It is possible to adapt to different gas supply methods by adding the configuration of gas pressure regulating and filtering devices.
Model |
A |
B |
C |
D |
E |
G (/NA,/O |
L |
M |
||
HTB 23W (/NA ) |
550 |
375 |
610 |
100-240 |
133 |
r |
r |
— |
165-195 |
12 (M10) |
HTB40W (/N./L./C) |
655 |
430 |
950 |
150-350 |
170 |
11/2- |
r |
11/2" |
185-225 |
14 (M12) |
HTB60W (/N,/L,/C ) |
780 |
515 |
1205 |
170-400 |
170 |
11/2" |
r |
2- |
185-225 |
14 (M12) |
HTB 80W ( /N.L ) |
780 |
515 |
1270 |
220-440 |
205 |
11/2" |
11/2" |
2- |
240 |
18 (M16) |
HTB100W (/N,L,/C ) |
780 |
515 |
1295 |
220-440 |
230 |
11/2" |
11/2" |
DN65 |
276 |
18 (M16) |
HTB120W ( /N./L./C ) |
830 |
530 |
1350 |
240-460 |
230 |
2- |
11/2" |
DN65 |
276 |
18 (M16) |
HTB150W (/N./L./C) |
830 |
530 |
1450 |
240-460 |
230 |
2- |
2- |
DN65 |
276 |
18 (M16) |
HTB 200W (/N./L./O |
985 |
860 |
1480 |
300-500 |
190 |
2- |
2- |
DN65 |
240 |
18 (M16) |
HTB250W (/N./L./C ) |
985 |
890 |
1480 |
300-500 |
190 |
DN69 |
2" |
DN100 |
240 |
18 (M16) |
HTB series small and medium-sized double-stage fire gas burner technical parameters
Model |
HTB23W/N |
HTB40W/N |
HTB60W/N |
HTB8OW/N |
HTB100W/N |
HTB120W/IN |
HTB150W/N |
HTB200W/N |
HTB250W/N |
|||||||
Output power |
KW |
93-267 |
174-464 |
232-696 |
348-928 |
464-1160 |
580-1392 |
696-1740 |
812-2320 |
928-2900 |
||||||
ibKcal/h |
8-23 |
15-40 |
20-60 |
30-80 |
40-100 |
50-120 |
60-150 |
70-200 |
80-250 |
|||||||
Control method |
Fully automatic two-stage fire control (proportional control method orders are acceptable) |
|||||||||||||||
Apply the most gas |
Natural gas (NG, LNG) |
|||||||||||||||
Standard inlet pressure |
Pa |
2000 |
5000 |
|||||||||||||
mm H20 |
200 |
500 |
||||||||||||||
Adaptable Pressure Range |
Pa |
1500-5000 |
4000-10000 |
|||||||||||||
mm H20 |
150-500 |
400-1000 |
||||||||||||||
Design fuel Low heat detection |
MJ/Nm3 |
35.53 ( 8500Kcal/Nm3) |
||||||||||||||
Adapted environment Temperature |
•c |
15-60 |
||||||||||||||
Torch monitoring method |
ionization |
UV ultraviolet type | ||||||||||||||
Applicable power supply |
AC220V /50Hz/1(p |
|
AC380V/50Hz/3<p |
|||||||||||||
Motor power |
KW |
0.25 |
0.55 |
1.1 |
1.5 |
2.2 |
2.2 |
3.0 |
4.0 |
4.0 |
||||||
Protection level |
IP |
40 (can be increased according to the order requirements) |
||||||||||||||
Mounting flange form |
Sliding adjustable method |
|||||||||||||||
Heating air volume adjustment method |
Synchronous servo-electric adjustment |
|||||||||||||||
Gas inlet connection size |
r |
11/2- |
11/2" |
11/2* |
11/2- |
2" |
2・ |
2- |
DN65 |
Model |
HTB23W/L |
HTB40W/L |
HTB60W/L |
HTB8OW/L |
HTB100W/L |
HTB120W/L |
HTB150W/L |
HTB200W/L |
HTB250W/L |
|
Output power |
KW |
93-267 |
174-464 |
232-696 |
348-928 |
464-1160 |
580-1392 |
696-1740 |
812-2320 |
928-2900 |
ibKcal/h |
8-23 |
15-40 |
20-60 |
30-80 |
40-100 |
50-120 |
60-150 |
70-200 |
80-250 |
|
Control method | Fully automatic two-stage fire control (proportional control method orders are acceptable) | |||||||||
Applicable gas | Liquefied Petroleum Gas (LPG) | |||||||||
Standard inlet pressure |
Pa |
2800 |
5000 |
|||||||
mm H20 |
280 |
500 |
||||||||
Adaptable pressure Van Hoard |
Pa |
2000-5000 |
4000-10000 |
|||||||
mm H20 |
200-500 |
400-1000 |
||||||||
Low Design Concordance |
MJ/Nm3 |
100.32 ( 24000Kcal/Nm3) |
||||||||
Adapted environment Temperature |
•c |
-15-60 |
||||||||
Flame monitoring method | Ionization type | UV ultraviolet type | ||||||||
Applicable power supply |
AC220V/ |
|
AC380V/50Hz/3<p |
|||||||
Motor power |
KW |
0.25 |
0.55 |
1.1 |
1.5 |
2.2 |
2.2 |
3.0 |
4.0 |
4.0 |
Protection level |
IP |
40 (can be lifted off upon order) | ||||||||
Mounting flange form | Sliding adjustable flange | |||||||||
Combustion air volume adjustment method | Synchronous servo-electric adjustment | |||||||||
The most air inlet interface size |
r |
r |
r |
11/2" |
11/2" |
11/2* |
11/2- |
11/2" |
2" |
Contact Us