HTA series small and medium-sized single section fire gas burner
keyword:
Category:
HT series all-in-one gas burner adopts natural gas and LPG as fuel, and is divided into single-stage fire, double-stage fire and proportional adjustment type according to the operation control mode.
1、Single-stage fire: only one section of fire output, the operation mode is on/off type. The use of single-stage fire is generally a low-power burner.
2、Double-stage fire: there are two stages of fire power, large and small fire, according to the control of the boiler thermostat (or pressure controller) to achieve a small fire (a fire) / large fire (= fire) 1 off conversion between the operation.
3, proportional adjustment type: can achieve smooth, proportional adjustment of the combustion volume in the output range. According to the signal from the equipment temperature or pressure controller, the burner can operate at any working point in the output range to keep the balance of the system input and output load and meet the system requirements for high-precision load control.
Using natural gas (NG, LNG), liquefied petroleum gas (LPG) as fuel, single-stage fire full automatic switching mode control.
Suitable for small boilers, hot water furnaces, heating furnaces, hot air furnaces, paint booths, spray painting equipment, die-casting machines, drying equipment, heat treatment equipment and other small and medium-sized thermal energy equipment where the accuracy of load control (temperature, pressure, etc.) is not required to achieve simple, convenient and economical applications.
▪ Safe and reliable fully automatic program control
◎ Fully automatic program control operation, and monitor the combustion status throughout the process, the control method is safe and reliable;
◎ Automatic start/stop can be realized according to the setting of control parameters such as temperature or pressure of heat-using equipment, and load control is simple and convenient;
◎ Equipped with gas safety solenoid valve with safety cut-off and flow adjustment function to ensure the safety of gas supply and cut-off;
◎ The use of ion induction fire detection device to achieve accidental flame out protection function, to ensure the flame burning safety and stability;
◎ Equipped with gas pressure and air pressure safety protection switch, and can easily realize external chain control to ensure safe operation.
◎ Good combustion performance and easy maintenance structure
◎ Carefully designed airflow mixing form, fully ensure the flame burning safety and stability and full combustion;
◎ Combustion volume and combustion air volume can be set and adjusted in the output range, and output control and good combustion effect can be realized through adjustment.
Â- Combined assembly of combustion head and flame stabilizing device, without removing the burner, the internal components can be easily removed for maintenance;
◎ With the sliding installation flange, the installation length of the burner is adjustable, and non-standard length models are also available to suit different furnace chamber structures.
Model |
A |
B |
C |
D |
E |
G (/N,/L,/C) |
L |
M |
||
HTA6 (/N, /L) |
400 |
275 |
460 |
50-150 |
95 |
3/4" |
3/4" |
一 |
130- 150 |
8 (M6) |
HTA10 (/N,/L,/C) |
480 |
275 |
460 |
50-150 |
95 |
3/4" |
3/4" |
1" |
130- 150 |
8 (M6) |
HTA17 (/N,/L) |
550 |
375 |
610 |
80-240 |
114 |
3/4" |
3/4" |
— |
165-195 |
10 (M8) |
HTA26 (/N,/L, /C) |
550 |
375 |
610 |
100-240 |
133 |
V |
3/4" |
1/2" |
165-195 |
10 (M8) |
HTA40 (/N, /L) |
655 |
430 |
950 |
150-350 |
170 |
11/2" |
1H |
一 |
185- 225 |
14 (M12) |
HTA60 (/N, /L) |
780 |
515 |
1205 |
170-400 |
170 |
11/2M |
1" |
— |
185 -225 |
14 (M12) |
HTA series small and medium-sized single-stage fire gas burner technical parameters
Model |
HTA6/N |
HTA10/N |
HTA17/N |
HTA26/N |
HTA40/N |
HTA60/N |
|
Output power (output power range) |
KW |
23-70 |
46-116 |
81-197 |
116- 302 |
174-464 |
232- 696 |
104Kcal/h |
2-6 |
4-10 |
7-17 |
10-26 |
15-40 |
20-60 |
|
Control method | Fully automatic single-stage fire control (proportional control method orders are acceptable) | ||||||
Applicable gas |
天然气(NG、LNG) |
||||||
Standard inlet pressure |
Pa |
2000 |
|||||
mm H20 |
200 |
||||||
Adaptable pressure range |
Pa |
1500-5000 |
|||||
mm H20 |
150-500 |
||||||
Design fuel low calorific value |
MJ/Nm3 |
35.53 (8500Kcal/Nm3) |
|||||
Adaptation to ambient temperature |
°C |
-15*60 |
|||||
Applicable power supply |
AC220V/50HZ/10 |
AC380V/50HZ/30 |
|||||
Motor power |
KW |
0.12 |
0.18 |
0.18 |
0.25 |
0.55 |
1.1 |
Protection level |
IP |
40 (Protection level can be increased upon request) |
|||||
Mounting flange form | Sliding adjustable flange | ||||||
Gas inlet connection size |
3/4" |
3/4" |
3/4" |
1" |
11/2" |
11/2" |
Model |
HTA6/N |
HTA10/N |
HTA17/N |
HTA26/N |
HTA40/N |
HTA60/N |
|
Output power |
KW |
23-70 |
46-116 |
81-197 |
116- 302 |
174-464 |
232- 696 |
104Kcal/h |
2-6 |
4-10 |
7-17 |
10-26 |
15-40 |
20-60 |
|
Control method | Fully automatic single-stage fire control (proportional control method orders are acceptable) | ||||||
Applicable gas | Liquefied Petroleum Gas (LPG) | ||||||
Standard inlet pressure |
Pa |
2800 |
|||||
mm H20 |
280 |
||||||
Adaptable pressure range |
Pa |
2000- 5000 |
|||||
mm H20 |
200-500 |
||||||
Design fuel low calorific value |
MJ/Nm3 |
100.32 (24000Kcal/Nm3) |
|||||
Adaptation to ambient temperature |
°C |
-15-60 |
|||||
Applicable power supply |
AC220V/50HZ/10 |
AC380V/50HZ/30 |
|||||
Motor power |
KW |
0.12 |
0.18 |
0.18 |
0.25 |
0.55 |
1.1 |
Protection level |
IP |
40 (Protection level can be increased upon request) |
|||||
Mounting flange form | Sliding adjustable flange | ||||||
Gas inlet connection size |
3/4" |
3/4" |
3/4" |
3/4" |
1" |
1" |